Modular Pipe-Rack Structural Steel & Skid Fabrication QA/QC Supervision
Resident welding & NDT supervision, AWS D1.1 structural UT/MT weld checks, padeye examination, and shop protective coating inspection prior to site erection.
Operational Context
Inspection / Technical Challenge
Maintaining uniform weld quality, MTC traceability, and primer DFT compliance across multiple simultaneous structural bays prior to heavy road transport.
Scope & Execution Approach
Enforced strict ITP hold points from incoming steel heat-number verification through fit-up, preheat, shear-wave UT on full-penetration moment connections, MT on lifting padeyes, and SSPC-PA 2 DFT sign-off.
Documented Outcomes
- Traceable heat-number, welder stamp, NDT, and coating records compiled into indexed module MRBs.
- Lifting padeyes verified free of surface cracks prior to heavy rigging deployment.
- Eliminated field fit-up and touch-up delays prior to site structural erection.
Mandatory fit-up and consumable-oven daily audits cut ultrasonic weld repair rates dramatically across heavy plate girders.
Field Photography


Planning a Comparable Inspection or Coatings Project?
Share your asset details, applicable engineering codes, and target project window with our technical team to initiate a quotation review.