Encoded PAUT & TOFD Volumetric Verification on Live Process Piping Tie-Ins
Full encoded PAUT + TOFD volumetric weld examination and MT/VT surface verification across 142 tie-in girth welds replacing radiography inside congested live process blocks.

Filter representative NDT, protective coating, lifting, and turnaround QA/QC engagements by industrial sector, service pillar, technical method, or asset category.
Showing 10 of 10 records
View Case Studies Only
Full encoded PAUT + TOFD volumetric weld examination and MT/VT surface verification across 142 tie-in girth welds replacing radiography inside congested live process blocks.

Controlled abrasive blasting to Sa 3, Bresle soluble-salt decontamination, dehumidified multi-coat phenolic epoxy lining, and 100% low/high-voltage holiday verification.

Scheduled turbine outage VT, wet fluorescent & dry MT on rotor journals, diaphragm grooves, casing studs, and main steam piping welds plus turnaround closeout QA/QC.

Dual-rope access structural ultrasonic thickness gauging, weld MT checks, and zone-wide overhead Dropped Object Prevention (DROPS) audit.

Resident welding & NDT supervision, AWS D1.1 structural UT/MT weld checks, padeye examination, and shop protective coating inspection prior to site erection.

Vendor quality surveillance, flange face & weld verification, hydrostatic pressure test witnessing, and Manufacturing Record Book compliance auditing.

Targeted LRUT guided-wave screening combined with local insulation-window visual/UT thickness verification across high-risk wet-insulation circuits.

Turnaround Internal Rotary Inspection System (IRIS) ultrasonic examination across cleaned exchanger tube bundles to establish plugging and re-tubing decisions.

Dedicated QA/QC supervision, WPS/PQR verification, fit-up & purge hold-point inspections, and traceable Manufacturing Record Book compilation.

Coastal surface preparation audit, soluble chloride testing, fresh-water desalination washing, Sa 2.5 blasting, and high-build marine epoxy-polyurethane coating QC.
Share your asset details, applicable engineering codes, and target project window with our technical team to initiate a quotation review.