Skip to main content
PhoenixInspections
Combining LRUT Screening & Targeted UT Windows to Detect Under-Insulation Piping Corrosion
CASE STUDY • OIL & GAS

Combining LRUT Screening & Targeted UT Windows to Detect Under-Insulation Piping Corrosion

Targeted LRUT guided-wave screening combined with local insulation-window visual/UT thickness verification across high-risk wet-insulation circuits.

1. Asset Context

Asset: Insulated Carbon Steel Process Pipe-Rack Headers (6" to 14" NB) · Sector: Oil & Gas · Location: Niger Delta Process Plant (Onshore Gas & Condensate Processing Facility — Anonymized)

2. Technical Challenge

Hundreds of meters of clad, thermally insulated overhead piping operating in the 60°C–115°C Corrosion Under Insulation (CUI) temperature window exhibited external aluminum jacketing damage, making 100% full scaffolding and insulation stripping commercially and operationally prohibitive.

3. Scope & Technical Approach

Stripped short 0.5 m collar access bands at strategic intervals to deploy Long Range Ultrasonic Testing (LRUT) guided-wave rings, screening straight runs and pipe-support interfaces rapidly. Every flagged LRUT anomaly category was then selectively stripped and verified via direct visual cleaning, pit-depth gauging, and zero-degree UT mapping.

4. Execution Constraints

Elevated overhead pipe-rack access above active utility corridors, wet weather, and strict insulation reinstatement scheduling.

5. Verified Findings & Client Operational Value

  • Targeted insulation stripping exclusively onto LRUT-flagged suspect zones and breached cladding points rather than blanket stripping.
  • Confirmed localized pitting beneath damaged jacketing near sleeper clamp zones using calibrated high-resolution UT.
  • Provided circuit-by-circuit wall-thickness datasets enabling targeted weld overlay/coating remediation prior to rain season peak.
6. Lessons & Engineering Considerations

LRUT excels as an axial screening filter, not a standalone pit-depth sizing method; pairing LRUT with disciplined local UT verification delivers both rapid coverage and engineering-grade wall thickness proof.

TECHNICAL & COMMERCIAL ENQUIRIES

Need Inspection or QA/QC Support?

Share your asset details, applicable engineering codes, and target project window with our technical team to initiate a quotation review.