Baseline & Trending Condition Surveys
Establishes repeatable isometric-indexed thickness monitoring points and corrosion circuits, calculating short-term and long-term corrosion rates across successive surveys.
- Piping circuit condition monitoring and injection-point/dead-leg erosion checks
- Storage tank floor, shell strake, and roof thickness trending
- Remaining-life inspection interval planning input
- • Process piping circuits
- • Storage tanks
- • Pressure vessels & exchangers
Updated P&IDs/isometrics, circuit operating specs, clean calibrated scan spots.
Uniform CML spot readings may miss highly localized pitting unless supplemented by scanning UT, C-scan corrosion mapping, or LRUT/profile RT.
Isometric-Linked CML Thickness Databases, Corrosion-Rate Trending Sheets, and Anomaly Reports.