External Corrosion & CUI Condition Surveys
Systematic walkdowns identifying coating breakdown grades (ISO 4628), crevice moisture traps, pipe-support contact corrosion, damaged cladding, and localized ultrasonic remaining-wall measurement.
- Corrosion Under Insulation (CUI) risk walkdowns and window inspections
- Pipe-rack, sleeper contact, and deck penetration corrosion grading
- Baseline corrosion-rate tracking across recurring inspection intervals
- • Insulated vessels & piping
- • Coastal pipe racks & sleepers
- • Offshore decks & tank roofs
Jacket/cladding inspection windows, pit-depth gauges, and ultrasonic step-wedge calibration.
Visual screening of insulated lines indicates moisture-ingress risk at breached jacketing; confirming true metal loss beneath intact cladding requires insulation window stripping, profile RT, or LRUT screening.
Condition-Graded Corrosion Survey Atlas, CUI Risk Register, and UT Thickness Matrices.